Description
Benefits:
The Heart Sure BP100 Upper-Arm Blood Pressure Monitor is easy to use with its simple one-touch operation. It features last reading memory and displays blood pressure values and pulse rate.
- Simple one-touch operation
- Fully automatic inflation
- Last reading memory
- Soft Medium Cuff – 22-32cm
- Display of Blood Pressure values and Pulse rate
- 4 x AA Batteries – Appox 1000 measurements
- Durable pump with lower-noise output
- 2 year warranty
Directions:
- Please read the full Instructions for Use provided with the product prior to using.
- Avoid bathing, drinking alcohol/caffeine, smoking, exercising and eating for 30 minutes before taking a measurement
- Rest for at least 5 minutes before taking the measurement
- Sit upright on a chair with your legs uncrossed and feet flat on the floor, with your back and arm being supported
- Remove tight-fitting clothing from your arm. Do not roll up a tight sleeve. Do not place the arm cuff over thick clothes
- Wrap the arm cuff firmly in place around the left upper arm. Please see instruction manual if needing to use the right arm.
- The bottom edge of the arm cuff should be 1 to 2 cm above your elbow
- The air tube should be on the inside of your arm and aligned with your middle finger
- Rest your arm on a table so that the arm cuff is at the same level as your heart
- Ensure a solid connection of the air plug and cuff to the main unit
- Ensure you remain still and do not talk during the measurement
- Press the START/STOP button
- The cuff will inflate and a result will display on the screen (approx. 30-60 secs)
- The reading will be automatically saved in the memory
Package Contents:
Main unit, arm cuff, instruction manual, 4 x AA batteries
Warning and Disclaimers:
Always read & follow the instructions for use & health warnings. For people with high blood pressure. Consult your doctor to evaluate the readings. Check your device periodically for accuracy.
- Please read all Safety Warnings provided with the product prior to use.
- Consult your physician before using the device for any of the following conditions: common arrhythmias such as atrial or ventricular premature beats or atrial fibrillation, arterial sclerosis, poor perfusion, diabetes, pregnancy, pre-eclampsia, masectomy, renal disease or severe blood flow problems or blood disorders as cuff inflation can cause bruising
- Always consult your doctor. Self-diagnosis of measurement results and self-treatment are dangerous
- Do not adjust medication based on measurement results from this blood pressure monitor. Take medication as prescribed by your physician. Only a physician is qualified to diagnose and treat High / Low Blood Pressure
- The monitor is not intended to be a diagnostic device
- Do not use the unit for any purpose other than measuring blood pressure
- Do not use the device on the injured arm or the arm under medical treatment
- Do not wrap the arm cuff on the arm while being on an intravenous drip or blood transfusion
- Consult your physician before using the device on the arm with an arterio-venous (A-V) shunt
- Do not apply or inflate the arm cuff around any body parts other than your upper arm
- Do not take measurements more than necessary. It may cause bruising due to blood flow interference
- Remove the arm cuff if it does not start deflating during the measurement
- The air tube or the AC adapter cable may cause accidental strangulation in infants
- Keep out of reach of children. Contains small parts that may cause a choking hazard if swallowed
- If there are any abnormalities during the measurement, remove the arm cuff
- Do not use this device on infants, children or persons who cannot express themselves
- Do not inflate the arm cuff more than necessary
- Stop using this monitor and consult your doctor if you experience skin irritation or discomfort
- Use only the approved arm cuff for this unit. Use of other arm cuffs may result in incorrect measurement results
- Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit
- Do not use the device with other medical electrical (ME) equipment simultaneously
- Do not use this monitor in areas containing high frequency (HF) surgical equipment, magnetic resonance imaging (MRI) equipment, computerized tomography (CT) scanners or in oxygen rich environments
- Follow the battery/ AC adaptor instructions carefully
More from:
Barcode: 4975479494215
Customer Reviews
Payment & Security
Your Payment Information is Processed Securely. We do Not Store Credit Card Details Nor Have Access To Your Credit Card Information.